CTI Bibliography of Technical Papers - Mechanical Draft TowersRevised 2009 To add a paper to your shopping cart, click on the paper's order number button.
| Mechanical Draft Towers |
| Order Number | Title | Author | Date |
|
|
Cooling Tower Basin Evaluation and Repair |
Tom Kline, Structural Preservation Systems |
2009 |
| Abstract: Mechanical draft cooling towers are critical fixed assets that need to be maintained and remain in service in order to cool various plant operations and systems. Essentially, the cooling tower basin in mechanical draft technology serves a two-fold purpose, one as containment for the cooling water and two as the foundation for supporting overlaying "fill" structures. Almost all of these basin structures are constructed of conventionally reinforced concrete, either partially or totally placed below grade. Their service environment subjects them to various aggressive deterioration mechanisms including embedded metal corrosion, original construction defects, environmental degradation (i.e. freeze-thaw, algae growth, etc.) as well as chemical attack resulting in erosion and structural section loss. Since these structures contain process water and function as support foundations, the existing condition of these structures should be evaluated regularly and repairs performed should conditions warrant, on a timely basis. Evaluation techniques exist, both non-destructive (NDT) and semi-destructive (SDT), which can serve as tools in assessing in-site conditions, either on or offline. Additionally, the paper will highlight case histories of cooling tower basin evaluations and subsequent repair program implementation. |
|
|
Feasibility of Seawater Cooling Towers for Large-Scale Petrochemical Development |
Dr. Shahriar Eftekharzadeh and Dr. Muin M. Baasiri, Bechtel Corporation and Paul A. Lindahl, Jr., Marley Cooling Technologies |
2003 |
| Abstract: The major feasibility issues concerning the applicability of Mechanical Draft Seawater Cooling Towers for large-scale petrochemical development in the hot-humid Arabian Peninsula (Gulf) region were investigated. Issues addressed were tower thermal performance, permissible hot and cold-water temperatures, scaling and bio-fouling, drift and impact on corrosion, environmental impacts, O&M concerns, and life-cycle costs. It was found that seawater cooling towers can satisfy the cooling needs of large-scale petrochemical development in the hot humid Gulf region, without significant problems. Cost of cooling was found to be less than the conventional once-through system normally used. Based on the findings of this study, plans are underway to double the size of one of the largest petrochemical complexes in the world, located in the region. The findings of this study constitute a major step forward for the cooling technologies industry. |
|
|
Partial Collapse and Rebuild of the Conesville Unit 4 Mechanical Draft Cooling Tower |
Frank L. Michell & Walt Demjanenko, American Electric Power Service Corp. |
1995 |
| Abstract: ON January 31, 1993, the north side of the No. 4A mechanical draft-cooling tower serving Columbus Southern Power's Conesville Unit 4 collapsed; forcing the 800 MW coal fired generating unit out of service. The cause of catastrophic structural failure, tower reconstruction program and considerations for preventing similar failures in the future will be reviewed. |
|